Gasket Replacement; Inspect The Vent System Annually; Check The Gas Flame Regularly; Stove Disassembly - Vermont Castings Intrepid INDVRCB Homeowner's Installation And Operating Manual

Direct vent, rear vent gas heater
Hide thumbs Also See for Intrepid INDVRCB:
Table of Contents

Advertisement

Intrepid® Direct Vent - Rear Vent Gas Heater
NOTE: Shown
without top for
clarity.
Fig. 82 Release the latches to release the glass frame.

Gasket Replacement

The Intrepid Gas Heater uses a 'tadpole' type gasket
to seal between the glass panel and the frame. In time,
this gasket can become brittle and compressed and
should be replaced. New gasket is available from your
dealer.
Shut off the gas supply and allow the stove to cool.
Wear safety goggles and a dust mask.
1. Remove the Front, Glass Frame and Glass Panel.
(Figs. 81, 82) Remove the old gasket. Use a ra-
zor blade to separate the glass and gasket from
the frame, and to clean the glass of any remaining
cement or bits of gasket. Use a cold chisel if neces-
sary.
2. Determine the correct length of gasket by laying it
ST391a
out around the edge of the glass. Allow an extra 1 -
Pinnacle
2" (25-50 mm). Mark the spot to be cut. Use a utility
knife.
release latches
3. Starting on a long edge, remove about 6" of the pro-
6/00
tective paper strip and apply the flat adhesive face
of the gasket around the outside-facing edge of the
panel. Continue around the panel, applying about 6"
at a time and being careful to not stretch the mate-
rial. Do not overlap the gasket ends. (Fig. 83)
4. Apply a thin bead of high temperature silicone
rubber sealant along the inside corner of the glass
frame, all around the perimeter. Place the flat
gasketed side of the glass panel back into the steel
frame. Pinch the rounded inside-facing gasket mate-
rial to bulk it up.
5. Replace the glass frame and front panel as previ-
ously described.
Fig. 83 Wrap the gasket material around the outside edge of
the glass.
38
ST179
glass gasket detail
11/99

Inspect the Vent System Annually

Have the vent system inspected annually by a quali-
fied technician. Shut off the main gas supply before
inspecting the system. Both the inner exhaust pipe and
the outer combustion supply pipe must be checked to
confirm that they are unblocked and in good condition.

Check the Gas Flame Regularly

To ensure the stove is operating properly, check the
ST391a
flames periodically to confirm they match Page 31,
Figure 65. The flames will be blue during the first 15-20
minutes of operation, and will gradually turn to yellow
after that.
Do not use your stove if the flame pattern differs from
that shown here. Contact your Vermont Castings dealer
or a qualified technician for help.
If there is ever a need to remove the firebox assem-
bly from the stove shell, support the firebox with solid
stands about 6" (152 mm) tall under the left and right
outer edges of the firebox base. Do not set the firebox
assembly directly on the floor; this can damage the
control valve and/or the gas lines from the valve to the
firebox.
Before removing the firebox from the shell, disconnect
the on/off switch wires from the valve. If the assembly
includes the optional fan, disconnect the fan rheostat.
If the installation includes a wall thermostat, disconnect
the thermostat leads from valve.
Disconnection and reconnection to the gas line should
only be done by a qualified gas service technician.
Upon reinstallation, the vent system must be sealed to
the firebox as discussed in the venting section. Also
be sure the logs are placed in the firebox correctly, as
shown on Page 29, Figures 58-61.
ST179

Stove Disassembly

20012761