DXV-60 EXTERIOR VENT LOCATIONS AND RESTRICTIONS
∨ -
Vent Terminal
A =
Clearance above grade, veranda, porch, deck, or balco-
ny (*18 inches (45 cm) minimum)
B =
Clearance to window or door that may be opened
(*12 inches (30 cm) minimum.
C =
Clearance to permanently closed window (minimum 12
inches (30 cm) recommended to prevent condensation
on window)
D =
Vertical clearance to ventilated soffit located above the
terminal within a horizontal distance of two feet (60
cm) from the center-line of the terminal (18 inches (46
cm) minimum). Vinyl surfaces require 24" min.
E =
Clearance to unventilated soffit (18 inches (46 cm)
minimum). Vinyl surfaces require 24" min
F =
Clearance to outside corner - six inches (15 cm)
G =
Clearance to inside corner - 24 inches (60 cm)
A vent shall not terminate directly above a side-walk or paved driveway which is located between two single family
dwellings and serves both dwellings.
Only permitted if veranda, porch, deck, or balcony, is fully open on a minimum of two sides beneath the floor.
* As specified in CGA B1:19 Installation Codes (1991). Note: Local codes or regulations may require different clearances.
HIGH ALTITUDE INSTALLATION INFORMATION: Prior to installing at altitudes higher than 7500, please con-
tact the Mendota technical service department for specific venting requirements and venting restrictions.
FIGURE 3: Exterior Vent Locations
∧ -
Air Supply Inlet
H =
I =
J =
K =
L =
M =
8
≡ -
Area where terminal is not permitted
*Not to be installed above a meter/regulator assembly
within three feet (90 cm) horizontally from the center-line
of the regulator
Clearance to service regulator vent outlet (*6 feet (1.8m)
minimum)
Clearance to non-mechanical air supply inlet to building or
the combustion air inlet to any other appliance.
(*12 inches (30 cm) minimum.
Clearance to a mechanical air supply inlet (*6 feet (1.8 m)
minimum)
† Clearance above paved side-walk or a paved driveway
located on public property (*7 feet (2.1 m) minimum)
Clearance under veranda, porch, deck, or balcony (*24
inches (60 cm) minimum ‡)