TROUBLE SHOOTING MENDOTA GAS DXV FIREPLACE

SYMPTOM
1. Thin black coating (soot)
forms on viewing glass.
2. Humming or whistling
coming from Fireplace.
3. A change in flame appear-
ance or burner operation.
During initial installation the burner should be removed by qualified person and the air shutter opening checked to be cer-
tain that the shutter is set correctly at 1/8" to 1/4" open for Natural gas and 1/2" minimum open for L.P. gas.
NOTE: For altitudes above 5,000 ft., some variations may be required.
Be sure burner and logs are properly installed (see PAGEs Error! Bookmark not defined.-28). After burner has been
properly installed and operated for two to three hours, small additional adjustments to the air shutter may be necessary for
final flame appearance. These small shutter adjustments can be made by the following procedure:
NOTE: Very small changes in shutter settings make major changes in flame appearance.
1. Air shutter knob is behind the lower grill.
2. If flame is too "blue" slowly push air shutter control knob in small 1/16" increments until flame turns desired realistic
"orange."
3. If flame is too "orange" or is causing sooting on viewing glass pull air shutter control knob in approx. 1/16" incre-
ments until sooting stops. IF SOOTING DOES NOT STOP, TURN OFF UNIT AND CALL YOUR MENDOTA
SERVICE PERSON.
IMPORTANT: Try each new shutter setting approx. ½ hour before making additional changes. NOTE: Changes in
front burner flame can be made by re-arranging the coals. (See PAGEs Error! Bookmark not de-
fined.-28)
CAUTION: Any changes in pilot flame must be made by qualified person and checked with volt meter.
PROBABLE CAUSES
A. Incorrect gas pressure
B. Not enough combustion air
A. Normal operating noise.
A. A change in gas pressure.
B. Carbon dirt or lint.
FIGURE 7: Air Shutter Control
MAIN BURNER GAS FLAME ADJUSTMENT
CORRECTIVE ACTION
Have gas supplier check for correct gas pressure (7" W.C.
MAX Nat. Gas; 11" W.C. MAX LP Gas).
If sooting continues open air shutter on burner (see "Gas
Flame Adjustment" below).
If sooting still continues, shut off unit and call Mendota
service person.
NOTE: To clean glass - remove glass and wipe glass with
a soft cotton cloth or a dry paper towel.
Some noise is normal. It is caused by the gas supply flow-
ing through the gas orifice. It is expected from any gas
fireplace. The noise can be reduced by turning the Hi/Lo
Knob on the control. Turning down the flame will reduce
the heat output of the unit.
Have your gas supplier check for correct gas 7" W.C. Nat.
Gas; 11" W.C. LP Gas). If flame still needs adjustment see
"Flame Adjustment" below.
Clean out carbon, spider webs, lint, etc. from shutter area.
Logs and burner.
NEVER BLOCK AIR INTAKE OR OUTLET VENTS.