Also for use in mobile (manufactured) homes after first sale of home.
Tested to ANSI Z21.88-2002 – CSA 2.33-2002
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause property damage,
personal injury, or loss of life. Refer to the owner's information manual provided with this appliance. Installa-
tion and service must be performed by a qualified installer, service agency or the gas supplier. Use only glass
assemblies certified for use with this appliance. Do not operate with glass panel(s) removed, cracked,or broken.
Input Rating (Btu/hr) 0-610 m
Orifice (DMS) 0-610 m
Manifold Pressure (in w.c.)
Manifold Pressure, low (in w.c.)
Minimum Inlet Pressure (in w.c.)
This appliance is equipped for installation at 0-610 meters. This appliance must be installed in accordance with local codes if any; If
not, follow ANSI Z223.1. Mobile (Mfg.) home installations must adhere to Title 24 CFR, Part 3280.
CAUTION: Hot while in operation. Do not touch. Keep children, clothing, furniture, and flammable liquids or vapors away.
Electrical Rating: 120 volts 60 Hz Less than 1 Ampere; Less than 120 Watts
"CERTIFICATION LABEL REPRESENTATION"
_________________________________________________
NOT FOR USE WITH SOLID FUEL
_______________________________________________
_______________________________________________
MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION
Unit to floor
Unit to enclosure sidewalls
Unit top to ceiling
Vent to enclosed
Wall Pass-Through to framing
Vent to adjacent sidewall
Mantle above discharge air opening 18 in.
_______________________________________________
JOHNSON GAS APPLIANCE
DO NOT REMOVE OR COVER THIS LABEL
DXV60
NATURAL GAS
60,000
#43 & 30
3.5
1.7
5.0
1/8 in.
0 in.
4 in.
2 in.
1 in.
6 in.
CEDAR RAPIDS, IOWA
WH# __________________
41
PROPANE GAS
59,000
#48 & #55
10.0
3.6
11.0