1. Place both thumbs on lower door frame directly above Spring Loaded Door Holding Bar.
2. Reach fingers under Bar and pull Bar straight out from Fireplace front.
3. Pull Bar down and move Bar inward until Bar clears door frame - then release.
4. Repeat procedure for opposite Holding Bar.
5. Carefully lift door straight up until door frame "clears" the 3 Door Holding Tabs on top of firebox.
6. Pull door directly out from firebox front.
1. Center door in firebox opening. Move door inward until the 3 slots on door frame are directly above
the 3 Door Holding Tabs on firebox top.
2. Lower door so the 3 Tabs on firebox top fit through the 3 slots on the door frame. (i.e. "Hang" door on the 3 Tabs)
3. "Swing in" the lower edge of door until it touches lower firebox front.
4. Pull Holding Bar down and outward (away from Fireplace) until it clears door frame.
5. Raise Bar until it fits securely in Bar Holding Brackets on door frame.
6. Repeat procedure for opposite Holding Bar.
CAUTION: Holding Bars MUST be "level" and securely in place on Bar Holding Brackets holding glass door TIGHTLY
against firebox front. The spring-loaded door is a pressure relief safety system and must be positioned as
shown.
WARNING: DO NOT SEPARATE THIS APPLIANCE WITH THE GLASS REMOVED, CRACKED OR BROKEN.
REPLACEMENT OF GLASS SHOULD BE DONE BY A LISCENSED OR QUALIFIED SERVICE PERSON.

DXV DOOR OPERATION

TO REMOVE DOOR
TO REPLACE DOOR