Fireplace Insert Installation

Mantel Requirements

See Installation Clearances Addendum.

Masonry Fireplace Requirements

Must utilize a positive connection (full reline)
Entire fireplace, including chimney, must be clean and undamaged. Any damage must be repaired
prior to installation of the insert.
Chimney height: 15' (4.5M) minimum; 33' (10M) maximum (measured from base of insert).
Entire fireplace, including chimney, must meet local building requirements.

Hearth Requirements

Non-combustible hearth must extend 12" (300mm) in front of the insert and 4.625" (118mm) from
both sides of the insert
When installed over a timber floor:
Hearth must be a minimum of 75mm of non-
combustible masonry with 16mm of FC sheet
along with offcuts to provide air flow (see
illustration to the right).
NOTE: if using the "Lopi Flush Wood Zero
Clearance Box" (www.lopi.com.au) see the
instructions included with the zero clearance
box for hearth requirements.
When installed over a cement floor:
Hearth must be non-combustible.

Drafting Performance

This appliance relies upon natural draft to operate. External forces, such as wind, barometric pressure,
topography, or factors of the home (negative pressure from exhaust fans, chimneys, air infiltration, etc.),
may adversely affect draft. Travis Industries cannot be responsible for external forces leading to less
than optimal performance.

Insert Rollers

Two rollers are built into the back edge of the insert. This
allows the insert to be rolled into position by lifting the front
of the insert and pushing it into position (see
© Travis Industries
(for qualified installers only)
Figure 4
).
100-01291
Figure 4
4060512