Leveling Bolt Installation; Fettle Installation - Travis Industries Large Flush Owner's Manual

Large flush wood insert with hybrid-fyre technology
Table of Contents

Advertisement

Fireplace Insert Installation

Leveling Bolt Installation

MASONRY NOTE: Place a metal plate below the
bolts on masonry fireplaces to prevent damage to the
floor brick.
Two leveling bolts are pre-installed on the insert to
allow for proper leveling within the fireplace. To
access the bolts, remove the back corner firebricks
and cover plates "a" and "b"). The bolts are pre-
threaded to a weld-nut on the base of the insert. Use
a 3/4" (19mm) socket wrench to screw the bolts down
(clockwise) until the insert is level (see "c").
SEALING THE COVER PLATE: We recommend
sealing the cover plate with furnace cement (place on
underside of cover plate).
BOLT LENGTH: The included bolts allow
approximately 26mm of rise. If additional rise is
required, use a longer 1/2-13 thread bolt. Make sure
the additional bolt length does not interfere with the
cover plate.

Fettle Installation

The fettle is designed to prevent ash from spilling out of the firebox opening. It is held in place with two tabs
and slots at the front of the firebox (see pictures below). The fettle is optional and may be removed if desired.
© Travis Industries
(for qualified installers only)
a
100-01291
11
b
c
Figure 5
4060512