Mitsubishi Electric FR-A5NR Instruction Manual page 31

Transistorized inverter
Table of Contents

Advertisement

COMPUTER LINK FUNCTION
3) Station numbers do not have to be sequential and may be skipped, e.g. as shown below:
Computer
(2) Communication specifications
Refer to the following table and set the parameters: (%: Factory setting)
Parameter
Description
Number
Communication
332
speed
Stop bit length/
333
data length
Parity check
334
presence/absence
CR, LF instruction
341
presence/absence
CAUTION
The inverter communication will not error if the Pr. 333 "stop bit length" setting differs from the
actual data value.
Station 3
Station 0
Station number setting example
Instruction
Data Setting
Code
H20: Read
3, 6, 12, 24,
HA0: Write
48, 96
(When HFF=3)
H21: Read
HA1: Write
0, 1
(When HFF=3)
H22: Read
HA2: Write
0, 1, 2
(When HFF=3)
H29: Read
HA9: Write
0, 1
(When HFF=3)
Station 1
Station 21
3: 300bps, 6: 600bps, 12: 1200bps, 24: 2400bps,
%
, 192
48: 4800bps,96: 9600bps, 192: 19200bps
0, 10: Stop bit length = 1 bit
1, 11: Stop bit length = 2 bits
%
, 10, 11
0, 1: Data length = 8 bits
10, 11: Data length = 7 bits
0: No parity check
%
1: Odd parity
2: Even parity
0: Without CR and LF
%
, 2
1: With CR only
2: With CR and LF
25
Station 6
Definition