9) Response time
[Data transmission time formula]
1
Communication speed
(Baudrate)
*Refer to the Inverter Instruction Manual (Pr. 117 to Pr. 124).
*Communication specifications (Refer to the following table)
Name
Stop bit length
Data length
REMARKS
1 bit is always required for the start bit.
Minimum total number of bits: 9 bits, maximum total number of bits: 12 bits
Data transmission time
(Refer to the following formula)
Computer
Inverter
Inverter
Computer
Number of data
×
characters(*)
Number of Bits
1 bit
2 bits
7 bits
8 bits
Inverter data processing time
= waiting time
+
(setting × 10ms)
10ms or longer required
Data transmission time
(Refer to the following formula)
Communication specifi-
×
cations*
(Total number of bits)
Name
Parity check
Start bit
44
COMPUTER LINK FUNCTION
data check time
(12ms)
= Data transmission time (s)
Number of Bits
Yes
1 bit
No
0 bits
1 bit