COMPUTER LINK FUNCTION
!Example: Response time when forward (reverse) rotation command is given by communication
Data transmission time
20ms or more
(Refer to the calculation
example 1 on the right)
Computer
↓
Inverter
Inverter
↓
Computer
0
Inverter data processing time
= waiting time
+
data check time
(setting × 10ms)
(12ms)
10ms or longer required
Data transmission time
(Refer to the calculation
example 2 on the right)
Time
<Calculation example 1>
1)Baudrate = 9600 bps, number of data char-
acters = 12, stop bit length = 2 bits, data
length = 8 bits, parity check = yes, CR, LF
instructions = yes
1
×12×12 = 0.015s (15.0ms)
9600
2)Same conditions as above with the excep-
tion of baudrate = 19200 bps
1
×12×12 = 0.0075s (7.5ms)
19200
3)Same conditions as above with the excep-
tion of baudrate = 300 bps
1
×12×12 = 0.48s (480ms)
300
45
Need help?
Do you have a question about the FR-A5NR and is the answer not in the manual?