14
en | RADION receiver SD
Furthermore for UL hold up installations the internal reed switch is to be disabled. The door
window contact magnet will not be operative. The transmitter if used for hold up installations
shall be dedicated to a holdup installation only. Hold up alarm requires a UL Listed
Automation System at the Central Station to show distinction between a Hold Up Alarm and a
regular Burglar Alarm.
RADION keyfobs
To comply with UL 1023, RADION keyfobs shall be programmed with Forced Arm Bypass Max
set to 0.
3.3

B810 installation

Use the provided anchors and screws to mount the receiver in locations accessible for future
maintenance. Mount the receiver onto a wall.
For best receiver reception results, place the receiver in a central location among the
transmitters. For optimal communication results in situations where there is a long distance
between the transmitting device and the system receiver, it might be necessary to install
repeaters.
Notice!
Mount the receiver in a location away from metal objects. Metal objects (duct work, wire
mesh screens, boxes) reduce RF range.
3.3.1

B810 configuration

RADION Wireless System operates on a radio frequency of 433.42 MHz.
Configuring the address switch
The address switch determines the receivers numeric address value which the receiver will
use to report receiver status information to the control panel. Set the address to the receiver
prior to installation. Address 1 through 4 are valid address settings for the receiver. Use a
slotted screwdriver to set the address switch.
Address settings
The receiver address switches provide a single-digit setting for the receiver's address. The
receiver uses addresses 1 through 4. Addresses 0 and 5 through 9 are invalid and will cause
the receiver to enter into an SDI2 communication error state. This will cause the receiver to be
unrecognized by the control panel. Refer to your control panel documentation for information
on the valid addresses for that control panel. The figure below shows the address switch
setting for address 1.
Figure 3.1: Address switch set to 1
2014.03 | 06 | F.01U.261.834
For UL installations, a 2.2 K ohm shall be installed.
For UL installations, primary securement means shall be screws.
Reference Guide