Radion Pir; Walk Testing - Bosch Radion B810 Reference Manual

Radion receiver sd
Hide thumbs Also See for Radion B810:
Table of Contents

Advertisement

RADION receiver SD
7

RADION PIR

The RFPR-12-A is a high performance PIR motion detector that uses advanced signal
processing. An integrated wireless transmitter sends a battery report with each transmission,
and transmits a supervisory signal to the control panel. Features include:
Dimensions
Relative humidity
Temperature (operating)
Power/voltage
Battery replacement
Battery life
Device testing
Wall and cover tamper switch
Frequency
Table 7.1: Specifications
7.1

Walk testing

Perform a walk test to determine the boundaries of the coverage area.
Insert a slotted screwdriver into the designated hole to open the cover and then close the
detector cover to start a 90-sec Walk Test mode.
During this test mode, motion detected within the detector's coverage area causes a
transmitted alarm and LED activation. Each alarm will also extend the Test Mode. Adjust as
necessary.
Notice!
Excessive use of the Walk Test Mode may reduce battery life. Use only for initial setup and
maintenance testing.
Notice!
In the normal operating mode, an alarm can be transmitted only after three (3) minutes have
passed since the previous alarm restoral. This 3 minute lockout time reduces unnecessary RF
transmissions in high traffic areas, thereby extending battery life.
Bosch Security Systems, Inc.
12 m x 12 m (40 ft x 40 ft) coverage
Flexible Mounting Height
111.00 mm x 60.00 mm x 43.00 mm
(4.40 in x 2.40 in x 1.70 in)
0% to 93%, non-condensing
Functional range: -10°C to +49°C (+14°F to +120°F)
UL only: 0゚C to +49゚C (+32゚F to+120゚F)
One CR123A Lithium battery, 3 VDC (
Duracell DL123A , Panasonic CR123A, or Sanyo
CR123A. Check your battery yearly to ensure proper
functionality.
Up to 5 years
To ensure proper functionality, the device must be
tested at least once every year by an installer.
Transmits a tamper signal when someone removes the
device from its base or pulls it away from the wall.
433.42 MHz
Reference Guide
RADION PIR | en
35
)
2014.03 | 06 | F.01U.261.834

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents