Checks
A periodic check of the pilot and burner fl ames should
be made. Check after the fi re has been on for at least
30 minutes. The pilot fl ame must cover the tip of the
thermocouple probe.
The main burner fl ame
pattern will vary from
appliance to appliance
depending on the type of
installation and climatic
conditions.
Thermocouple
probe must be
in flame
The appliance area must
always be kept clear and
free from combustible
materials, gasoline and
other fl ammable vapors
and liquids.
Inspect the vent terminal
outdoors regularly to make
sure that dirt, snow, insects,
leaves, shrubs, trees do not
obstruct it.
Examine the whole vent
system regularly. We
recommend annually.
Batteries
CAUTION
DO NOT USE a screwdriver or other metallic object
to remove the batteries from the receiver or the
handset! This could cause a short circuit to the
receiver.
CAUTION
To avoid short-circuit to the receiver, position the
antenna so that it DOES NOT TOUCH the ignition
wire.
Low battery signal: page 33.
Owner's Information
With Logs
With Coals
With Rocks
Correct fl ame appearance
All appliances use four 1.5V AA alkaline batteries for
remote control receivers and the handset uses a 9V
alkaline battery.
Batteries are accessible by opening the bottom access
panel and removing the lid of the remote control
receiver.
Batteries should last one to two seasons, depending on
usage. Removing batteries in the off season will extend
battery life.
Manual On/Off Switch
In cases where you want to turn off your fi replace
and cannot do it with the remote control handset
(misplaced, lost, dead batteries, etc.) or if you need to
replace the receiver's batteries, you can turn off the
appliance with the manual switch located on the right
hand side of the valve.
If you are planning not to use your fi replace for a
prolonged period of time, remove the battery from the
remote handset and turn off the gas valve using the
manual ON/OFF switch.
ON
OFF
Valve
Switch
Servicing
If your appliance require any attention, contact your
supplier quoting the model number. It will be helpful if
the appliance serial number can also be quoted. This
is on the rating plate, which is on a chained, plate
accessible by opening the bottom access panel.
The repair parts are shown in the separate repair
parts leafl et. Please always quote part number and
description when requesting spare parts.