3

Technical data

General data
U
Dimensions
MS20-0800...
W x H x D
MS30-0802...
MS20-1600...
MS30-1602...
MS20-2400...
MS30-2402...
Weight
MS20-0800...
MS30-0802...
MS20-1600...
MS30-1602...
MS20-2400...
MS30-2402...
Voltage supply
Operating voltage
Overload current
protection at input
Isolation voltage
between operating
voltage and hou-
sing
Surrounding
Storage temperature
Humidity
Atmospheric pressure
Operating tempe-
Standard
rature
Extended
Pollution degree
Protection types
Laser protection
Protection types
1)
At 48 VDC power supply (voltage range C (18...60 VDC),
see table
"Combination options of the MS20/MS30 device versions" on page
EMV and stability
U
EMV interference
proof
EN 61000-4-2
EN 61000-4-3
MS20/MS30
Release 2.0 02/06
(surrounding air)
Discharge of static electricity
Contact discharge: test level 3
Air discharge: test level 3
Electromagnetic fields
Test level 3 (80 - 2000 MHz)
125 mm x 133 mm x 100 mm (140 mm
163 mm x 133 mm x 100 mm (140 mm
202 mm x 133 mm x 100 mm (140 mm
240 mm x 133 mm x 100 mm (140 mm
278 mm x 133 mm x 100 mm (140 mm
316 mm x 133 mm x 100 mm (140 mm
1)
610 g
(700 g
)
1)
740 g
(830 g
)
1)
880 g
(970 g
)
1)
1010 g (1100 g
)
1)
1030 g (1120 g
)
1)
1160 g (1250 g
)
18 to 32 V DC (voltage range A) or
18 to 60 V DC (voltage range C)
safety extra-low voltage (SELV/PELV), redundant
inputs decoupled. Relevant for North America:
Nec Class 2 power source 5 A maximum.
non-changeable fuse
800 V
Standard: -40 °C to +70 °C
Extended: -40 °C to +85 °C
10% to 95% (non condensing)
up to 2.000 m (795 hPa), higher altitudes on
demand
0 °C to +60 °C
-40 °C to +70 °C
2
Class 1 conforming to EN 60825-1 (2001)
IP 20
1)
)
1)
)
1)
)
1)
)
1)
)
1)
)
13)
1)
1)
A
B
4 kV
8 kV
8 KV
15 kV
10 V/m 20 V/m