100 Mbit/s F/O connection
U
100 MBit/s F/O ports (MTRJ-, ST- or DSC) enable the connection of ter-
minal devices or independent network segments in compliance with the
IEEE 802.3 100BASE-FX standard. These ports support:
D
full and half duplex mode
State on delivery: full duplex.
Note: Make sure, that you conncet LH ports only to LH ports, SM ports
only to SM ports and MM ports only to MM ports.
1 Gbit/s F/O connection
U
1 Gbit/s F/O ports (LC sockets) enable the connection of terminal
devices or independent network segments in compliance with the IEEE
802.3-2000 (ISO/IEC 8802-3:2000) 1000BASE-SX or 1000BASE-LX
standard. These ports support:
D
autonegotiation,
D
full duplex mode
State on delivery: autonegotiation.
Note: Make sure, that you conncet LH ports only to LH ports, SX ports
only to SX ports and LX ports only to LX ports.

AUI connection

U
AUI ports (Attachment Unit Interface) enable you to connect a terminal
device via an AUI cable in accordance with IEEE 802.3-2002.
These ports support:
D
SQE test
D
DTEPower monitor
State on delivery: both functions not enabled.
The housing of the Sub-D plug is electrically isolated from the lower
panel of the device.
Fig. 17:
Pin assignment of the AUI interface
Connect the ports of the media modules plugged into the basic module
as required in order to set up your industrial ETHERNET or expand your
existing network.
V Connect the data lines according to your requirements.
MS20/MS30
Release 2.0 02/06
shielding CO
Pin 8
n.c.
Pin 7
GND
Pin 6
output DI-A
Pin 5
shielding DI
Pin 4
Pin 3
input DO-A
output CI-A
Pin 2
shielding CI
Pin 1
Pin 15
n.c.
Pin 14
Schirmung 12 V
Pin 13
shielding 12 V
Pin 12
output DI-B
Pin 11
shielding DO
Pin 10
input DO-B
Pin 9
output CI-B