The following condition is reported in RM mode additionally:
D
Ring redundancy guaranteed. Ring redundancy is not monitored in the
delivery condition.
2.1.8

Connecting the terminal blocks, startup procedure

V Pull the terminal blocks off the device and connect the power supply
and signal lines.
MICE MS20/30
switch basic module
with 18 to 60 VDC
voltage range
Fig. 12:
Pin assignment of the 4-pin signal contact
V Mount the terminal block for the supply voltage and the signal contact on
the front of the device. Make sure that the snap lock snaps into place.
By connecting the supply voltage at the terminal block, you start the
operation of the device.
2.1.9

Assembling the device on the ISO/DIN rail, grounding

V You mount the device on a 35 mm hat rail according to DIN EN 60175.
V Attach the upper snap-in guide of the device into the hat rail and press it
down against the DIN rail until it snaps into place.
Note: The shielding ground of the connectable twisted pair lines is connected
to the lower panel as a conductor.
26
Power/signal contact 1:
1 =
+24 V (P1)
2 =
0 V
3,4 = Relay 1
Power/signal contact 2:
1 =
+24 V (P2)
2 =
0 V
3,4 = Relay 2
MICE MS20/30
switch basic module
with 18 to 32 VDC
voltage range
Power/signal contact 1:
1 =
2 =
3,4 = Relay 1
Power/signal contact 2:
1 =
2 =
3,4 = Relay 2
+24 V (P1)
0 V
+24 V (P2)
0 V
MS20/MS30
Release 2.0 02/06