2.1.4

Assembling the SFP modules

V To fasten a SFP module, first remove the protective cap over the socket.
V Insert the SFP module with the closed lock into the socket until you hear
it snap in.
Note: Only use SFP modules from Hirschmann.
Fig. 10:
Installation SFP module
2.1.5

Adjusting the DIP switch settings on the basic module

The 4-pin DIP switch in the bottom panel of the basic module provides you
with the following options:
DIP switch
Function
RM (Redundancy
When the HIPER-Ring function is
2)
Manager)
switched on, you can switch the RM
(Redundancy Manager) function on and
off (see "User Manual - Redundancy Con-
figuration").
1)
Ring port
Selecting the ports for the HIPER-Ring.
MS30: In the ON position, ports 1 and 2 in
module 2 are for connecting the HIPER-
Ring.
MS20: In the ON position, port 1 from
modules 1 and 2 are for connecting the
HIPER-Ring.
2)
Stand-by
With the redundant coupling of rings, you
assign the redundancy function to the
MICE in the redundant line (see "User
Manual - Redundancy Configuration").
Software Configu-
Give the software configuration priority
ration / DIP Confi-
ahead of the DIP switch position. In this
guration
case, the other switch positions are
meaningless.
MS20/MS30
Release 2.0 02/06
State of delivery
position OFF (RM function
not active)
position OFF (ports 1 and 2
of module 1 are for con-
necting the HIPER-Ring)
position OFF (normal
function)
position OFF (software
configuration has priority)
23