16
REMOVE BRACKETS FROM PRODUCT
WARNING!
Electrical Shock Hazard
Before continuing, ensure that the product is
disconnected from the power supply.
Failure to follow this warning may result in
electrical shock, injury or fire.
1
2
GROUND THE PANELS
18
Repeat for the other drawer
INTEGRATED MODELS ONLY - INSTALLING THE FRONT PANELS
1
3
WARNING!
Electrical Shock Hazard
To ground (earth) the panel bracket, connect
the ground (earth) wire from the product to
one of the tabs. Any custom metal component
(e.g. handle) that extends past the rubber seal
must be grounded (earthed) too.
Failure to follow these warnings may result in
electrical shock, injury or fi re.
ATTACH PANELS TO PANEL BRACKETS
17
1
Align bottom of panels
with bottom of brackets
ATTACH PANELS TO PRODUCT
19
2
1
2
There must be at least
5⁄8" (16mm) x6
16 mm x6
3 screws used each side
Important!
Break off and discard
the tab at the top
of the Lower Panel
Bracket.
3
Important!
Ensure the rubber seal
between the drawer
and panels is kept in
place.
2
Repeat for the other drawer
When refitting the
door pins,
ensure they are
orientated as shown.
18