Auto Repeater Function (Usa/Csa Versions Only) - Icom IC-V82 Instruction Manual

Icom america vhf transceiver, vhf transceiver instructions manual
Hide thumbs Also See for IC-V82:
Table of Contents

Advertisement

5
REPEATER OPERATION
■ Auto repeater function
The USA/CSA versions automatically activate the repeater
settings (duplex ON/OFF, duplex direction, tone encoder
ON/OFF) when the operating frequency falls within or outside
of the general repeater output frequency range. The offset
and repeater tone frequencies are not changed by the auto
repeater function. Reset these frequencies, if necessary.
q While pushing and holding [Y Y ] and [Z Z ], turn the power ON
to enter
INITIAL SET MODE
w Push [Y Y ] or [Z Z ] several times until "RPt" appears.
e Rotate [VOL] to select the desired condition.
• "OF"— the auto repeater function is turned OFF;
• "R1"— the auto repeater function activates duplex only;
• "R2"— the auto repeater function activates duplex and tone.
r Push [✱•
] (or [D•
ENT
20
(USA/CSA versions only)
.
]) to exit
INITIAL SET MODE
CLR
• Frequency range and offset direction
Frequency range
145.200–145.495 MHz
146.610–146.995 MHz
147.000–147.395 MHz
442.000–444.995 MHz
447.000–449.995 MHz
.
INITIAL SET MODE
USING
Duplex direction
"–" appears
"+" appears
"+" appears
"–" appears