5
REPEATER OPERATION
■ Auto repeater function
The USA version automatically activates the repeater settings
(duplex ON/OFF, duplex direction, tone encoder ON/OFF)
when the operating frequency falls within or outside of the
general repeater output frequency range. The offset and re-
peater tone frequencies are not changed by the auto repeater
function. Reset these frequencies, if necessary.
q While pushing and holding [Y Y ] and [Z Z ], turn the power ON
to enter
INITIAL SET MODE
w Push [Y Y ] or [Z Z ] several times until "RPt" appears.
e Rotate [VOL] to select the desired condition.
• "OF"— the auto repeater function is turned OFF;
• "R1"— the auto repeater function activates duplex only;
• "R2"— the auto repeater function activates duplex and tone.
r Push [✱
] (or [CLR]) to exit
ENT
25
(USA version only)
.
.
INITIAL SET MODE
• Frequency range and offset direction
Frequency range
145.200–145.495 MHz
146.610–146.995 MHz
147.000–147.395 MHz
INITIAL SET MODE
USING
Duplex direction
"–" appears
"+" appears