AC
POWER
The MiniMAC has switch-selectable settings to configure the power supply for
local conditions. The factory-default setting is indicated on the serial number label.
Always use the setting that is closest to the local AC supply.
Warning!
For protection from electric shock, the fixture must be grounded
(earthed). The power supply shall have overload and ground-
fault protection.
Important! Install fuse and verify that power supply settings match local
AC supply before use.
To change the volt age set ting
1 Disconnect the fixture from power.
2 Remove the 4 base cover bolts with a 4 mm Allen wrench. Move the cover out of
the way of the switches without disconnecting wires.
3 Set the 5-position switch (A) to the setting closest to the AC voltage. Use the
higher setting if the voltage is halfway between 2 settings. For example, use the
230 V setting instead of the 210 V setting for operation with 220 V power.
4 Set the 2-position switch (B) to the AC frequency (50 / 60 Hz).
5 Replace the cover and apply a new power setting label to the serial number
label.