Advertisement

3 Plug a data cable into the OUT socket of the first
fixture and the IN socket of the next fixture. Repeat as
required to connect up to 32 MiniMACs (Profiles and
Washes).
4 Insert a female termination plug (P/N 91613018) into
the IN socket of the first fixture. Inser t a male
termination plug (P/N 91613017) into the OUT socket
of the last fixture. A termination plug is an XLR
connector with a 120 ohm, 0.25 W resistor soldered
across pins 2 and 3.
5 On all fixtures, scroll to
O n
or
6 Set the trigger and pan/tilt options using the control panel on the master
fixture. Set the color and gobo options on the slave fixtures. See Table 6. Note:
The inverse pan and inverse tilt personalities may also be used to modify
behavior. See Table 4.
7 Disconnect the fixture from power to stop operation.
8 To disable stand-alone operation, set
22
EnA
Aut
, and press [enter].
Stand-alone operation
, press [enter], scroll to
E nA
OF F
to
Female
Termination Plug
Female XLR
1
2
120
3
P/N 91613018
.