To inst al l t he mai n fuse
Fuses are provided for 100 - 130 V and 200 - 250 V operation. Use only the fuse
specified for the operating voltage.
1 Locate the bag containing the fuse for your AC voltage. Insert the fuse in the
fuse holder. The holder may be packed with the other fuse.
2 Remove the label covering the mains input socket.
3 Insert the fuse holder in the empty slot in the mains input socket (C).
To inst al l a pl ug on t he power cable
The power cable must be fitted with a grounding-type cord cap that fits your power
distribution system. Consult an electrician if you have any doubts about proper
installation.
Following the cord cap manufacturer's instructions, connect the yellow and
green wire to ground (earth), the brown wire to live, and the blue wire to neutral.
The table below shows some pin identification schemes.
To apply power
Warning!
The power cables must be undamaged and rated for the
electrical requirements of all connected devices.
Important! Powering through a dimmer system can damage the fixture.
Connect the prepared cable to the mains input socket and the AC mains
distribution system. Do not connect the fixture to a dimmer system.
Wire
brown
blue
yellow/green
Pin
live
neutral
ground
Table 1: Cord cap connections
AC power
Marking
Screw color
"L"
yellow or brass
"N"
silver
green
7