Martin MiniMAC Wash User Manual page 19

Table of Contents

Advertisement

To connect f or cont rol ler operat ion
1 Connect a data cable to the controller's data output. If controller has a 5-pin
output, use a 5-pin male to 3-pin female adaptor cable (P/N 11820005). Lead the
cable from the controller to the first fixture and plug it into the data input.
2 Connect the output of the fixture closest to the
c o n t ro l l e r t o t h e i n p u t o f t h e n ex t f i x t u r e . I f
connecting to a fixture with reversed-polarity (pin 3
cold), insert a phase-reversing cable between the two
fixtures.
3 Continue connecting fixtures output to input. Up to
32 devices may be connected on a serial link.
4 Terminate the link by inserting a male termination
plug (P/N 91613017) into the data output of the last
f i x t u r e . A t e r m i n a t i o n p l u g i s s i m p ly a n X L R
connector with a 120 ohm, 0.25 W resistor soldered
across pins 2 and 3.
C O N T R O L L A B L E E F F E C T S
L A M P P O W E R
Lamp power can be switched on and off from the controller. When set up for
controller operation, and with the automatic lamp-on personality set to off, the lamp
remains off until a lamp-on command is sent.
Note: A peak of electric current many times the operating current is drawn briefly
when striking a lamp. Striking many discharge lamps at once may cause a voltage
drop that prevents lamps from striking or trips circuit breakers. When striking
multiple fixtures, space lamp-on commands at 5 second intervals.
The lamp must be allowed to cool for several minutes after turning it off before it
can be turned back on. To prevent accidental lamp-off commands, this command
can be partially disabled from the control panel: see page 14. If a hot lamp does not
strike, send the lamp off command and wait several minutes before trying again.
R E S E T
All effects can be reset to their index positions from the controller. To prevent
accidental resets, the command can be partially disabled from the control panel: see
page 14.
Controller operation
Male
Termination Plug
Male XLR
1
2
120
3
P/N 91613017
19