LF:
Persistent low flow problems. (Displays on the fifth occurrence of the HFL
message within 24 hours.) Heater is shut down, but other spa functions
continue to run normally. Follow active required for HFL message. Heating
capacity of the spa will not reset automatically. You may press any pad to reset.
dr:
Inadequate water detected in heater. Check water level in spa. Refill if
necessary. If the water level is okay, make sure the pumps have been
primed. Press any pad to reset
drY:
Inadequate water detected in heater. (Displays on third occurrence of dr
message.) Spa is shut down. Follow action required for "dr" message. Spa
will not automatically reset; you may press any pad to reset.
Pr:
When your spa is first energized, it will go into Priming mode. It will last for up
to four or five minutes and then the spa will begin to heat and maintain the
water temperature in the Standard mode.
- - F; - - C:
Temperature unknown. After the pump has been running for two minutes,
the temperature will display.
- - -:
The temperature is not current. The spa is in Economy or Sleep mode. The
pump may have been off for hours. If you wish to see the current spa tempera-
ture, either switch to Standard mode or turn Jets 1 on for at least two minutes.
SbY:
Standby mode has been activated by pressing a pad combination on the user
panel. Press any pad to leave Standby Mode and return to normal operation.
Additional Diagnostics for Epic and Destiny models:
rtC: Hardware failure. Contact dealer.
PSt: Hardware failure. Contact dealer.
CrC: Firmware install problem. Contact dealer.
CFE: Configuration error, spa cannot start up. Contact dealer.
GFI: Spa could not trip GFCI. Contact dealer, continued operation could be unsafe.
StU: A pump appears to be stuck on, causing the water temperature to
creep up, possibly to hazardous levels. POWER DOWN SPA IMMEDIATELY.
DO NOT ENTER THE WATER. Contact dealer.
HOt: A pump appears to have been stuck on the last time spa was pow-
ered. POWER DOWN SPA IMMEDIATELY. DO NOT ENTER THE WATER.
Contact dealer.
NOTE: If power is shut off or a power outage occurs the 240V system has a
battery backup. All user settings are retained.