Marquis Spas Destiny Owner's Manual page 13

Marquis spas
Hide thumbs Also See for Destiny:
Table of Contents

Advertisement

1.
Press TEMP+, then JETS 1, then SPA LIGHT.
2. Press TEMP+ repeatedly until "gFC" is displayed, then press JETS 1.
3. Press TEMP+ until "gC.n" is displayed, then press JETS 1 to clear the GFCI
Status; you will see gS.A" displayed verifying that the GFCI Status has been
set to "Armed". The system will exit this menu in 30 seconds if no buttons are
pressed.
*When you enter the GFCI menu, it always shows you the current status first.
"gS.P" means that it's Passed (and will do no further automated GFCI Trip Tests),
"gS.A" means that it's Armed (and will do an automated GFCI Trip Test in 24
hours, unless a manual GFCI Trip Test is done before that). ("gS.t", which you are
unlikely to see unless you've just initiated a Trip manually, means that it's about to
Trip within the next dozen seconds or so.)
120 Volt
120 Volt spas shall be plugged into a properly grounded, grounding type 15 amp
receptacle on a dedicated circuit. A dedicated circuit is a circuit with no other
components that consume power, such as lights, televisions, radios, computers,
or other electronic devices. These could cause your spa to malfunction by any
of the following: unusual text on the control panel, slow heating, poor jet action,
tripping house breaker, or blown fuses. Failure to follow these instructions could
lead to premature failure of spa components that would not be covered under
the warranty. The dedicated circuit shall meet the following specifications:
Convert 120 Volt to 240 Volt
120 Volt spas may be converted to operate on 240V, 50A. All connections must
be made by a licensed electrician.
1. Disconnect the power by unplugging the power cord from the receptacle,
removing the cord from the terminal block on the circuit board, and storing it
with your owner's manual.
2. Locate the white wire connecting J11 to J32 on the circuit board. Remove the
wire and discard.
3. For 50A operation, move dip switch 10 to the OFF position.
4. Install 240V power as indicated in the 240 Volt section.
5. Rated 240V, 60Hz, 50A, three wires (#6 copper) plus ground (#8 copper), [4
wires total].
GFCIs are available from your authorized dealer.
Improperly wired spas are beyond Marquis Corp. control and are not covered
under the warranty. Other items beyond Marquis Corp. control include, but are
not limited to, damage resulting from: improper connections; accidents; failure to
follow procedures and instructions defined in the Marquis Spas
tions; cleaning agents; and natural occurrences including but not limited to
rodent or insect infestation, mold, lightning and other acts of nature.
I N S T A L L A T I O N
• Rated 120V, 60Hz, 15A (2 wires plus ground)
• Circuit breaker or fuse size: 15A
• The receptacle must be at least 5 feet (1.52 m) from
the spa.
• The 15 foot GFCI power cord provided with the
spa must be plugged directly into the receptacle.Do
NOT use an extension cord or any other adaptor.
Actual exposed length of cord will vary by model,
but will never be less than 12 feet.
I N S T R U C T I O N S
®