Troubleshooting; Lcd Diagnostic Messages - Marquis Spas Destiny Owner's Manual

Marquis spas
Hide thumbs Also See for Destiny:
Table of Contents

Advertisement

LCD DIAGNOSTIC MESSAGES

The advanced technology built into the spa allows it to perform a number of
self-diagnostic system checks and it can display a variety of messages in the
LCD window on the control panel.
OHH:
Over heat protection. If a malfunction occurs and the spa water reaches
112°F (44°C), the system completely shuts down. In such a condition, DO
NOT ENTER THE WATER. Turn off all power to the spa. Remove spa cover
and allow water to cool. Once the heater has cooled, turn on power to the
spa, then reset by pushing any pad. If spa does not reset, shut off the
power to the spa and contact your authorized Marquis Spas
service. Several conditions could lead to overheating, for example, low water
level, shut-off valves closed while heater is on, dirty filter, and restriction in the
plumbing lines. After the power is turned back on, the spa will not restart itself
until the water temperature within the spa drops to a lower, predetermined
temperature.
OHS:
Over heat protection. The spa has shut down. One of the sensors has
detected that the spa water is 110°F (43.3°C). DO NOT ENTER THE WATER.
Turn off all power to the spa. Remove spa cover and allow water to cool.
Once the heater has cooled, turn on power to spa, then reset by pushing
any pad. If spa does not reset, shut off the power to the spa and contact
authorized Marquis Spas
ICE:
Freeze protection has been activated. Contact your authorized Marquis
Spas
®
dealer for service.
SnA and SA:
A sensor that is plugged into the Sensor "A" jack is not working. The spa
turns off. Contact your authorized Marquis Spas
Snb and SB:
A sensor that is plugged into the Sensor "B" jack is not working. The spa
turns off. Contact your authorized Marquis Spas
SnS and SN:
Sensors are out of balance. If this is alternating with the temperature, it may
just be a temporary condition. If the display shows only this message (peri-
odically blinking), the spa is shut down. Contact your authorized Marquis
Spas
®
dealer for service.
NOTE: If power is shut off or a power outage occurs the 240V system has a
battery backup. All user settings are retained.
HFL and HL:
A substantial difference between the temperature sensors was detected.
This could indicate a flow problem. Check water level in spa. Refill if neces-
sary. If the water level is okay, make sure the pumps have been primed. If
problem persists, contact your authorized Marquis Spas
T R O U B L E S H O O T I N G
®
dealer for service.
®
dealer for
®
dealer for service.
®
dealer for service.
®
dealer for service.
55

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents