Clustering Support; Inventory Checklist; Features At A Glance - IBM TotalStorage FAStT600 Installation And User Manual

Fibre channel storage server
Hide thumbs Also See for TotalStorage FAStT600:
Table of Contents

Advertisement

| |
Table 5. Features at a glance
|
|
|
General
|
|
|
v Modular components:
|
|
|
– High-capacity Fibre Channel disk
|
|
|
drives
|
|
|
– RAID controllers
|
|
|
– Power supplies
|
|
|
– Cooling fans
|
|
|
v Technology:
|
|
– Support for disk arrays
|
|
|
– Support for clustering
|
|
|
– Fibre-channel host interface
|
|
|
– Redundant data storage, cooling
|
|
system, power system, and RAID
|
|
|
controllers (Model 60U/60X only)
|
|
|
– Hot-swap technology for power
|
|
|
supplies and RAID controllers (Model
|
|
|
60U/60X only)
|
|
– Hot-swap technology for
|
|
|
fibre-channel hard drives and fans
|
|
(all models).
|
Attention: You will lose data if you
|
attempt to hot swap the controller and
|
power supply components in a
|
FAStT600 single-controller storage
|
server (Model 6LU/6LX).
|

Clustering support

Inventory checklist

|
|
|
|
|
|
|
|
|
|
|
4
IBM TotalStorage FAStT600 Fibre Channel Storage Server: Installation and User's Guide
v User interface:
– Built-in power, activity, and fault light
emitting diodes (LEDs)
– Identification labeling on customer
replaceable units (CRUs), rear LEDs,
switches, and connectors
– Easy-to-replace drives, power
supplies, RAID controllers, and fans
Disk drive storage
2-Gbps Fibre Channel enclosure
Maximum drives per storage server: 14
Attached Expansion Units
For Model 60U/60X, attachment of
FAStT EXP700 drive expansion units
requires one or more EXP700
Attachment option (or feature)
upgrades for the FAStT600
2-Gbps connection only
Clustering is a means of sharing array groups among controllers to provide
redundancy of controllers and servers. This redundancy is important if a hardware
component fails. If a hardware component failure occurs in a cluster, another server
takes ownership of the array group.
Clustering requires software specific to your operating system. For more information
about clustering, go to the following Web site:
www.ibm.com/pc/us/compat/nos/cert.shtml
After you unpack the storage server, verify that you have the following items:
Hardware
IBM FAStT600 storage server comes with the following components:
v RAID controllers
– 2 controllers on Model 60U/60X
– 1 controller on Model 6LU/6LX
v Power supplies
– 2 power supplies on Model 60U/60X
– 1 power supply on Model 6LU/6LX
v Power cords
– Two power cords on Model 60U/60X
– One power cord on Model 6LU/6LX
v Two fan units
RAID controllers
v Technology and interfaces:
– Fibre Channel: 40-pin fibre-channel
disk drives
– Fibre Channel interface:
- For Model 60U/60X, six small
form-factor pluggable (SFP)
modules for incoming and
outgoing fibre-channel cables
(three SFPs on each RAID
controller).
- For Model 6LU/6LX, four SFP
modules for incoming
fibre-channel cables (two SFPs on
each RAID controller).
– Two 2-Gbps fibre-channel host-side
connections per controller

Advertisement

Table of Contents
loading

Table of Contents