Location Of Sfps And Fiber-Optic Cables; Unlocking The Sfp Module Latch - Plastic Variety - IBM TotalStorage FAStT600 Installation And User Manual

Fibre channel storage server
Hide thumbs Also See for TotalStorage FAStT600:
Table of Contents

Advertisement

Figure 68. Location of SFPs and fiber-optic cables
Protective cap
Figure 69. Unlocking the SFP module latch - plastic variety
88
IBM TotalStorage FAStT600 Fibre Channel Storage Server: Installation and User's Guide
Attention:
Handle and install fiber-optic cables properly to avoid degraded
performance or loss of communications with devices. When working with
fiber-optic cables, do not pinch them, step on them, or locate them in aisles or
walkways. Do not overtighten the cable straps or bend the cables to a radius
smaller than 38 mm (1.5 in.).
3. From the RAID controller that has failed, remove the fibre-channel cables from
the SFPs. The location of these components is shown in Figure 68.
SFP module
Fiber-optic
cable
After removing the fibre-channel cables, insert the protective caps.
4. Use the following procedure to remove the SFPs from the RAID controller that
has failed.
a. Remove the LC-LC fibre-channel cable from the SFP module. For more
information, see "Handling fiber-optic cables" on page 33.
b. Unlock the SFP module latch:
v For SFP modules that contain plastic tabs, unlock the SFP module latch
by pulling the plastic tab outward 10°, as shown in Figure 69.
Plastic tab
o
10
v For SFP modules that contain wire tabs, unlock the SFP module latch by
pulling the wire latch outward 90°, as shown in Figure 33 on page 36.
Raid controller
SFP module

Advertisement

Table of Contents
loading