Diagnostic error codes

Note: In the following error codes, if XXX is 000, 195, or 197, do not replace a
FRU. The description for these error codes are:
000
195
197
For all error codes, replace the FRU or take the action indicated.
Note: See Chapter 7, "Parts listing, Type 6224," on page 107 to determine which components are replaceable by the
customer (CRU), and which components must be replaced by a field service technician (FRU).
Error code/symptom
001-250-000
(Failed system board ECC)
001-250-001
(Failed system board ECC)
001-XXX-000
(Failed core tests)
001-XXX-001
(Failed core tests)
005-XXX-000
(Failed video test)
011-XXX-000
(Failed COM1 serial port test)
011-XXX-001
(Failed COM2 serial port test)
014-XXX-000
(Failed parallel port test)
015-XXX-001
(USB interface not found, board damaged)
015-XXX-015
(Failed USB external loopback test)
015-XXX-198 (Remote Supervisor Adapter
II installed or USB device connected during
USB test)
020-XXX-000
(Failed PCI interface test)
030-XXX-00N
(Failed SCSI interface test)
The test passed.
The Esc key was pressed to stop the test.
Warning; a hardware failure did not occur. The test could not be run due to
some other problem.
FRU/action
v System board
v System board
v System board
v System board
1. Video adapter (if installed)
2. System board
1. Check loopback plug connected to externalized serial port.
2. Check cable from externalized port to system board.
3. System board.
1. Check loopback plug connected to externalized serial port.
2. Check cable from externalized port to system board.
3. System board.
v System board
1. System board
1. Make sure the parallel port is not disabled.
2. Run the USB external loopback test again.
3. System board.
1. If Remote Supervisor Adapter II is installed as an option,
remove it and rerun test.
Note: If Remote Supervisor Adapter II is present as a standard
installation, do not remove it; the test cannot be run.
2. Remove USB devices and rerun test.
3. System board.
v System board
v If N=0, system board; if N>0, SCSI adapter in slot N.
Chapter 6. Symptom-to-FRU index
89