Matching As/400 Parameters For 3651 Retail Controllers - IBM AS/400 Hardware User Manual

Ibm network hardware - networking hardware user manual
Hide thumbs Also See for AS/400:
Table of Contents

Advertisement

To configure an AS/400 to a retail controller, see the following.
v "Matching AS/400 parameters for 3651 retail controllers"
v "Matching AS/400 parameters for 3684 retail controllers" on page 70
v "Matching AS/400 parameters for 4680/4690 LINE parameter" on page 72
v "Matching AS/400 parameters for 4680/4690 LINK parameter" on page 73
v "Matching AS/400 parameters for 4684 retail controllers" on page 74

Matching AS/400 parameters for 3651 retail controllers

You must coordinate several parameter values for retail communications. These values are specified for
the AS/400 system and the 3651 retail controller. The following table lists those AS/400 parameters that
must match values for the 3651 retail controllers.
Before you match parameters for 3651 retail controllers, you need to match AS/400 controller, device, and
line descriptions parameters with the host system.
AS/400 parameters are listed in alphabetical order; the commands on which the parameters are specified
are included in the rightmost column of the table.
For more information about configuring the 3651 controller, see the IBM Programmable Store System
Language and Host Services: Macro Reference
To configure the AS/400 to a 3651 retail controller, use the following table.
AS/400 Prompt
Connection type
CNN
Duplex
DUPLEX
Exchange identifier
EXCHID
Modem data rate
MODEMRATE
NRZI data encoding
NRZI
68
Version 5
AS/400
3651 Definition
Parameter
Statement
QFHOST
QFHOST
QFHOST
QFHOST
QFHOST
3651 Parameter
SDLCLIN
Value specified for the AS/400 CNN parameter on the
CRTLINSDLC command must match the values
specified for bits 2 and 3 of the 3651 SDLCLIN
parameter.
SDLCLIN
Value specified for the AS/400 DUPLEX parameter on
the CRTLINSDLC command must match the value
specified for bit 6 of the 3651 SDLCLIN parameter.
SENDID
3651 SENDID parameter must match the last 5 digits of
the EXCHID parameter specified on the AS/400
CRTLINSDLC command. (This parameter is used only
for switched line communications.)
RECVID
3651 RECVID parameter must match the last 5 digits of
the EXCHID parameter specified on the AS/400
CRTCTLRTL command.
SDLCLIN
Value specified for the AS/400 MODEMRATE parameter
on the CRTLINSDLC command must match the value
specified for bit 5 of the 3651 SDLCLIN parameter.
SDLCLIN
Value specified for the AS/400 NRZI parameter on the
CRTLINSDLC command must match the value specified
for bit 1 of the 3651 SDLCLIN parameter.

Advertisement

Table of Contents
loading

Table of Contents