Example: Connecting AS/400 to a 5494 controller connected by X.21
Configuration parameters must be coordinated when you connect an AS/400 system to a 5494 controller.
The following diagram shows the AS/400 parameters and 5494 parameters that need to match when you
use X.21.
5494
Field
Subfield
AS/400 Value
AA
-
*X21
2
-
-
Chapter 7. Communicating with remote workstation controllers
5494 Value
4
5494 configuration values must
match the values specified for
the LINKTYPE parameter on
the CRTCTLAPPC command.
Select 2 for X.21 network
connections.
-
Values specified in the AS/400
controller description and for
the 5494 Remote Control Unit
must match. This value must
also be specified as the last 2
digits of the AS/400 EXCHID
parameter.
Notes