Matching As/400 Device Description Parameters For A Remote As/400 System - IBM AS/400 Hardware User Manual

Ibm network hardware - networking hardware user manual
Hide thumbs Also See for AS/400:
Table of Contents

Advertisement

AS/400 Prompt
Exchange identifier
EXCHID
Initial connection
INLCNN
Link protocol
LINKPCL
Remote control point
RMTCPNAME
name
Remote network
RMTNETID
identifier
Data link role
ROLE
X.25 reverse charging RVSCRG
Switched network
SNBU
backup
Source service access
SSAP
point
Station address
STNADR
Note: For asynchronous controllers (CRTCTLASC command), if the remote system controller description specifies
RMTVFY(*YES), the local system controller description must specify a local identifier (LCLID parameter) and local
location name (LCLLOCNAME parameter). The remote system must also create a configuration list with the LCLID
and LCLLOCNAME values from the local system controller description.
For more information on AS/400 parameters, see the Communications Configuration
Matching AS/400 device description parameters for a remote AS/400
system
You must coordinate communications configuration parameters between local and remote AS/400 systems.
The parameters are described in the following table. This table shows those prompts and parameters that
must be coordinated when you specify device descriptions for the local and remote AS/400 systems.
To configure a local AS/400 to a remote AS/400:
v See "Connecting one AS/400 to another AS/400 system" on page 37 for an example of connecting one
AS/400 to another AS/400 system.
v Use the following table for the device description.
36
Version 5
AS/400
Remote AS/400
Parameter
Parameter
EXCHID
INLCNN
LINKPCL
LCLCPNAME
LCLNETID
ROLE
RVSCRG
SNBU
DSAP
STNADR
Notes
If used, the local AS/400 controller description EXCHID
must match the remote AS/400 line description
EXCHID. The first three digits of the exchange identifier,
known as the block number, is
You can use the WRKLIND command to determine this
value.
Values specified for each system must be coordinated;
INLCNN(*ANS) must not be specified for both systems.
For X.25 connections, values specified for each system
must match; both must be *QLLC or *ELLC.
RMTCPNAME specified on the local AS/400 system
controller description must match the local control point
name specified in the network attributes of the remote
AS/400 system.
RMTNETID specified on the local AS/400 system
controller description must match the local network ID
specified in the network attributes of the remote AS/400
system.
The value specified for the local AS/400 controller
description ROLE parameter must match the remote
AS/400 line description ROLE value.
Values specified for each system must be coordinated.
Values specified for each system must match.
SSAP specified for the local AS/400 system must match
the DSAP specified in the remote AS/400 controller
description.
Values specified for each system must match, unless
both controller descriptions specify ROLE(*NEG).
for the AS/400 line.
book.