Resynchronization Of Suspended Volume Using Tso - IBM System storage DS6000 Series Redbook

Copy services with ibm system z
Hide thumbs Also See for System storage DS6000 Series:
Table of Contents

Advertisement

16.1 Resynchronization of suspended volume using TSO

To resynchronize a volume that is in a suspended state we need to obtain information such
as serial numbers, WWNNs, CCA and LSS numbers. We can obtain this information using
the CQUERY command, and then use it to reestablish the Metro Mirror pairs. Example 16-1
shows the CQUERY command and the output information it provides.
Example 16-1 CQUERY command to obtain information
ANTP8802I CQUERY DEVN(6400)
ANTP0090I CQUERY FORMATTED LVL 3 739
VOLUME REPORT
************** PPRC REMOTE COPY CQUERY - VOLUME ********************
*
*
*DEVICE
*------ --------- ---------- ----------- ---------
* 6400 PRIMARY.. SUSPEND(3)
*
* PATHS PFCA SFCA STATUS: DESCRIPTION
* ----- --------- ------ -------------------
*
1
*
*
*
* SUBSYSTEM
* ----------- ----------------
* PRIMARY.... 500507630EFFFCA0
* SECONDARY.1 500507630EFFFCA0
********************************************************************
ANTP0001I CQUERY COMMAND COMPLETED FOR DEVICE 6400. COMPLETION CODE: 00
We see from the output that the device number 6400 is currently a primary volume and is in
suspend state. The SSID, CCA, LSS, and serial number information is on the right side of the
display for both the primary (0002, 00, 00, and AAVCA) and secondary devices (0003, 00, 01,
and AAVCA). The path information is also shown (one path from primary Fibre Channel adapter
0000 to secondary Fibre Channel adapter 0100).
We can see that this volume is mirrored to the same DS6000 via a loopback path (the serial
number for the primary and secondary DS6000 are the same).
We now have the information required for our Metro Mirror commands.
Resynchronize the pair
The CESTPAIR command can be used to establish a Metro Mirror pair from TSO. We already
had a pair established in the previous scenario; however, it was suspended. Therefore, we
had to resynchronize it so that the pair would be in duplex state again. Example 16-2 on
page 187 demonstrates how to use the CESTPAIR command with the MODE(RESYNC)
parameter to accomplish this.
186
IBM System Storage DS6000 Series: Copy Services with IBM System z
LEVEL
STATE
PATH STATUS SERIAL#
CRIT(NO).......
CGRPLB(NO). 0000000AAVCA 0000000AAVCA*
0000 0100
13
PATH ESTABLISHED...
---- ----
00
NO PATH............
---- ----
00
NO PATH............
---- ----
00
NO PATH............
WWNN
(PRIMARY)
(SECONDARY) *
SSID CCA LSS SSID CCA LSS*
ACTIVE..
0002 00 00
LIC LEVEL
-----------
5.0.00.0000
SERIAL#
*
--------- *
0003 00 01 *
*
*
*
*
*
*
*
*
*
*

Advertisement

Table of Contents
loading

Table of Contents