IBM x Series 200 Hardware Maintenance Manual page 104

Ibm computer drive hardware maintenance manual
Table of Contents

Advertisement

Error Code/Symptom
187
(VPD serial number not set.)
188
(Bad EEPROM CRC #2)
189
(Three attempts were made to
access the server with invalid
passwords)
201
(Memory test error, see
"Memory Settings" on page
31.) If the server does not
have the latest level of BIOS
installed, update the BIOS to
the latest level and run the
diagnostic program again.
229
(Cache error)
289
(DIMM has been disabled by
user or system, see "Memory
Settings" on page 31.)
301
(Keyboard or keyboard
controller error)
303
(Keyboard controller error)
602
(Invalid diskette boot record)
604
(Diskette drive error)
662
(Diskette drive configuration
error)
96
Hardware Maintenance Manual: xSeries 200
1.
Set serial number in Setup
2.
System Board
1.
Run Configuration/Setup
2.
System Board
1.
Run Configuration/Setup, enter the administrator password
2.
System Board.
1.
Run memory diagnostics.
2.
DIMM
3.
System Board
1.
Microprocessor
1.
Run Configuration/Setup, if disabled by user
2.
Disabled DIMM, if not disabled by user.
1.
Keyboard
2.
System Board
1.
System Board
2.
Keyboard
1.
Diskette
2.
Diskette Drive
3.
Cable
4.
System Board
1.
Run Configuration/Setup and Diagnostics
2.
Diskette Drive
3.
Drive Cable
4.
System Board
1.
Run Configuration/Setup and Diagnostics
2.
Diskette Drive
3.
Drive Cable
4.
System Board
FRU/Action