Serveraid; Undetermined Problems - IBM x Series 200 Hardware Maintenance Manual

Ibm computer drive hardware maintenance manual
Table of Contents

Advertisement

ServeRAID

Undetermined problems

100
Hardware Maintenance Manual: xSeries 200
For ServeRAID error codes and procedures, refer to the Hardware Maintenance
Manual for the particular RAID adapter in the system being serviced.
You are here because the diagnostic tests did not identify the failure, the Devices List
is incorrect, or the system is inoperative.
Note:
A corrupt CMOS can cause undetermined problems.
If power problems are suspected:
1.
Power-off the computer.
2.
Be sure the system is cabled correctly.
3.
Remove or disconnect the following (one at a time) until you find the failure
(power-on the computer and reconfigure each time).
Any external devices
Surge suppressor device (on the computer)
Modem, printer, mouse, or non-IBM devices
Each adapter
Drives
Memory Modules (Minimum requirement = one 128 MB DIMM)
Note: Minimum operating requirements are:
a.
1 Power Supply
b. System Board
c.
1 Microprocessor
d. 1 Terminator Card in Slot 2
e.
1 Memory Module (minimum of 1 DIMM in slot labeled DIMM 1)
4.
Power-on the computer. If the problem remains, suspect the following FRUs in
the order listed:
Power Supply
System Board
Notes:
1.
If the problem goes away when you remove an adapter from the system, and
replacing that adapter does not correct the problem, suspect the system board,
then the power supply.
2.
If you suspect a networking problem and all the system tests pass, suspect a
network cabling problem external to the system.

Advertisement

Table of Contents
loading

Table of Contents