Error Code/Symptom
201-XXX-999
(Multiple DIMM failure, see
error text.)
202-XXX-001
(Failed System Cache test)
206-XXX-000
(Failed Diskette Drive test)
215-XXX-000
(Failed IDE CD-ROM test)
217-XXX-000
(Failed BIOS Fixed Disk test)
Note:
If RAID is
configured, the fixed
disk number refers to
the RAID logical
array.
217-XXX-001
(Failed BIOS Fixed Disk test)
Note:
If RAID is
configured, the fixed
disk number refers to
the RAID logical
array.
217-XXX-002
(Failed BIOS Fixed Disk test)
If RAID is
Note:
configured, the fixed
disk number refers to
the RAID logical
array.
264-XXX-0NN
(NN = SCSI ID of failing Tape
Drive)
264-XXX-999
(Errors on multiple tape
drives, see error text for more
info)
1.
See error text for failing DIMMs
1.
Microprocessor CPU 1
1.
Cable
2.
Diskette Drive
3.
System Board
1.
CD-ROM Drive Cables
2.
CD-ROM Drive
3.
System Board
1.
Fixed Disk 1
1.
Fixed Disk 2
1.
Fixed Disk 3
1.
Tape Cartridge, if user executed the Read/Write Tape Drive test (XXX = 256)
2.
SCSI or power cable connected to the tape drive with SCSI ID NN
3.
Tape drive with SCSI ID NN – refer to Help and Service Information appendix of
tape drive's User Guide.
4.
I/O Legacy Board or SCSI Controller – run SCSI Controller diagnostic to
determine of SCSI bus is functioning properly.
1.
See error messages/text in the PC Doctor error log for detailed information on
each individual tape drive error.
FRU/Action