Outputs; Output Status; Turn Output On/Off; Output Name - Bosch Solution 64 User Manual

Hide thumbs Also See for Solution 64:
Table of Contents

Advertisement

Solution 64 | User Guide

Outputs

Each Solution 64 Solution control panel has up to a maximum of
8 outputs. 4 outputs are available as standard with an additional
4 available when the optional output expander is fitted. Your
installer will advise you on the exact makeup and configuration of
you system.
Outputs > Commands >

Output Status

This menu allows you to view the status of each output.
1.
Ensure that the system is turned off.
2.
Press [MENU] + [4] + [0] + [0].
The keypad will display a list of outputs that the status may
be viewed.
3.
Using the [ ] and [ ] keys, highlight the output that you want
to view the status information, then press [OK] to select.
Alternatively, you can enter the output number and then
press [OK].
The keypad will display the following when the output is off
and OK:
Output 1 Name O001
Is Off and Ready
Press OK or MENU
The keypad will display the following when the output is off
and missing:
Output 1 Name O001
Is Off and Ready
Connection Trouble
Press OK or MENU
The keypad will display the following when the output is ON
and OK:
Output 1 Name O001
Is ON and Ready
Press OK or MENU
The keypad will display the following when the output is ON
and missing:
Output 1 Name O001
Is ON and Ready
Connection Trouble
Press OK or MENU
4.
Press [OK] to save and exit, or press [MENU] to exit without
saving.
18
Outputs > Commands >

Turn Output On/Off

This menu allows you to turn outputs that have been
programmed by your security company on or off. These outputs
can be programmed to control outside lighting, pool pumps,
watering systems etc.
1.
Press [MENU] + [4] + [0] + [1].
MENU 4-0-0
If a valid PIN is required, the keypad will prompt you to
enter your PIN.
2.
Use the [ ] and [ ] keys to select the output name that you
want to change, then press [OK] to select. Alternatively, you
can enter the output number, then press [OK].
3.
To toggle the output on or off, use the [ON] and [OFF] keys.
The keypad will display the following when the output is off:
To turn the output on, press [ON].
The keypad will display the following when the output is on:
To turn the output off, press [OFF].
4.
Press [OK] to save and exit, or press [MENU] to exit without
saving.
Outputs > Properties >

Output Name

This menu allows you to program the name for each output.
Each output name supports up to 16 characters.
1.
Enter [MENU] + [4] + [1] + [0].
A list of different outputs will display on the keypad.
2.
Use the [ ] and [ ] keys to select the output name that you
want to change, then press [OK] to select. Alternatively, you
can enter the output number, then press [OK].
The keypad will display the following:
Output 1 Name O001
Output is OFF,
To Turn ON,Press ON.
To Go Back Press OK
Output 1 O001
Output is ON,
To Turn OFF,Press OFF.
To Go Back Press OK
Output Name O001
Output 1
Press
OK to SAVE
Bosch Security Systems | 12/05 | BLCC110U
MENU 4-0-1
MENU 4-1-0

Hide quick links: