Functional characteristics
Machine control – Operating elements
5.1.4
Selecting MIG/MAG welding tasks
5.1.4.1
Setting the operating point (welding output)
This control works according to the twin-knob operation principle. To set the operating point, only the wire
speed and the welding voltage need to be set according to the material and the electrode diameter.
Operating
element
5.1.4.2
Setting the operating mode and runtime parameters
The parameter values set are preset in the JOB and can be modified if necessary.
Operating
element
34
Action
Result
Wire speed setting
Welding voltage setting
Action
Result
Select operating mode:
X x
Select welding parameter:
X x
The selected parameter is shown on the display
Set the parameter chosen
Non-latched
Latched
Spots
Interval
Set gas post-flow time "GnS"
(0.0 s to 10.0 s)
Set wire burn-back time "drb" (-50% to 50%)
Spot/interval time "t1" (0.1 s to 5.0 s)
Interval/pause "t2" (0.1 s to 2.0 s)
Item No.: 099-004934-EWM01