4.10 Boiler Operational Modes

There are three possible operational modes of the two boilers in the LaSpaziale Mini VII
20A model:
Both boilers are completely independent, turning on and off according to the
needs of each. Both can be on at the same time. This is the default mode with
the BOILER enabled and 20A mode selected using the internal 15A/20A switch.
The
BOILER
those that only drink espresso and do not need steam or hot water and want to
conserve energy. This can be used to keep the boiler off regardless of whether
the machine is running in 15A or 20A mode.
Important Tip: The state of the
maintained through On/Stby cycles, when the unit is unplugged, or if there
is a power failure.
The Mini VII can also be switched into Economy (15A) mode. In this mode, only
one boiler can be on at a time. The Mini VII automatically controls which is on
according to demand with preference going to the group boiler. This is useful for
those owning the 20A model but lacking a 20A circuit. How to do this is
described below.
Turning the Steam/Hot Water Boiler On and Off
1. The Mini VII must be in ON mode, not Standby for all operations below.
2. With the BOILER lamp on, press and hold the
lamp turns off. Neither steam nor hot water is available.
As noted above, the Mini V2 remembers the current state of the
button through Off/On cycles, when the machine is unplugged, and through
power failures.
3. Press the
BOILER
4. When the BOILER lamp is on (or blinking), steam and hot water are available.
Turning Economy (15A Mode) On and Off
1. The Mini VII must be unplugged and allowed to cool down first.
2. Remove any cups from the cup warming tray (7)
3. Remove the single screw in the front middle of the cup warming tray (7) as
shown in the photo below
S1 Mini Vivaldi II Owner's Manual
button can toggle the Boiler on and off. This mode is useful for
BOILER
button again until the BOILER lamp turns back on.
Page 11
button is kept in memory and is
BOILER
button until the BOILER
BOILER