Unity 4600 User's Manual
SP program
program: Either an integer between 1 and 65,535 (representing a number) or
an alphanumeric string (representing a name), preference being on a number to
resolve ambiguity.
Command changes selected program by Program Number (from PAT) or SDT
descriptor.
TEMP [format] [feed #] [carrier freq] [data rate] [FEC] [Tag Site] program#
time
For format, feed #, carrier freq, data rate, FEC, tag site, and program #, see
PERM command.
time: Length of insert in either HH:MM:SS format (valid range is 0:00:00 to
18:00:00, leading zeros OK to omit on hours) OR in number of seconds. (A
one-hour TEMP could have a parameters: of 1:00:00 or 3600.)
Command which performs a volatile temporary insert for an amount of time
given by time. Unit sets its temporary Unit Settings to the values given. <Note
that no label may be applied using this terminal command.>
TEMPCH value time
value: Either the value of a settings table entry number OR the Channel Label of
an entry, priority given to Label if any ambiguity. If an entry number, legal val-
ues range from 1 up to N (where N is number of Preset support this product).
time: Same as for TEMP.
Volatile command which sets volatile temporary Unit Settings to those
retrieved from the Preset table according to value for time given by time. Simi-
lar to TEMP command.
TEMPSENS
Command displays internal unit temperature if available.
wegener.com