Unity 4600 User's Manual
MARGIN margin_offset
margin_offset:Integer values between 0 and N in the form of x.x, representing
dB (to tenths of a dB). N is defined by individual IRD specifications for every
modulation/FEC combination.
Command sets the Margin Warning point. This provides warning to local users
that their Eb/No's are approaching the error-threshold where system perfor-
mance will collapse. (Supersedes SNR command.) A Local Control Command
(available from the terminal regardless of "Local Control Enable/Disable"
commands from the network).
MOVEP source destination
source: Preset Table entry number which will source Unit settings.
destination: Preset Table entry number to which the Unit settings will be
moved.
Command moves the Unit settings at the source entry to the destination entry.
The setting data at the original source entry is deleted and that entry position is
now considered unused. The setting data at the original destination entry is
then moved to the next lower unused Preset position. (One will always be
available because the entry that held the original source settings was made
"unused".)