Isolate From Generator Field (Dc Isolator) - Platinum 5500 R3-S2B User And Installation Manual

Table of Contents

Advertisement

Operation
5.2.3
ACTUAL operation display
The ACTUAL operation display is divided between two screens.
Screen 1: AC side
Screen 2: DC side

5.3 Isolate from generator field (DC isolator)

The DC isolator on the left side of the inverter enables the solar generator to be
switched on and off.
▪ PLATINUM® recommends activating the DC isolator once a year to
prevent the contacts from fusing together.
▪ PLATINUM® recommends switching off the mains voltage (AC) be-
fore switching off the DC isolator to minimise wear to the contacts.
28
The three phases of the AC side are displayed.
The inputs TA and TB of the DC side are displayed.
Position 0: Solar generator switched off
Position 1: Solar generator switched on
Installation and user guide PLATINUM® inverter 5500 R3-S2, 7000 R3-S2, 8000 R3-S2, 9000 R3-S2