INSTALLATION
TM-200 / TM-300 Miniature CCD Camera
2.2.3 Attaching the Video Output
Most users utilize the BNC connector for video output from the camera. Connect the output from the
camera to the input of your monitor, VCR or switching device. The input of the monitor should be
balanced for 75Ω termination. Standard RG-59 type coaxial cable should carry a full video signal for up
to 500 feet.
Users wishing to output the video and input the power and sync to a camera over a single cable can use
the PULNiX multi-conductor cables, such as the 12P-02, the KC-10, etc. The mini coaxial leads in
PULNiX multi-conductor cables are designed for short runs of no longer than 100 feet.
Note: Make sure that no extraneous wires are visible which could cause a short.
2.2.4 Attaching the Camera Lens
The TM-200/TM-300 camera accepts 1/2" or larger format size C-mount lenses. To attach the C-mount
lens to the camera, carefully engage the threads and rotate the lens clockwise until it firmly seats on the
mounting ring. Do not force the lens if it does not seat properly. Please note that some lenses with
extremely long flangebacks may exceed the mounting depth of the camera.
2.2.5 Back Focusing the Lens
To backfocus the TM-200 camera, first attach a C-mount lens in the lens mount. Be sure that the lens is
properly mounted.
Set the lens focus to infinity (if the lens is a manual iris, set the iris to a low f-stop while still retaining a
well-illuminated image). Obtain the best focus possible at this setting, then loosen the 3 miniature hex
head set screws locking the focus ring in place. Now turn the entire lens and focus ring assembly back
and forth until the best image is obtained. Tighten the focus ring set screws. Your backfocus is now set.
2.2.6 Auto-Iris Lens Setup
Auto-iris lenses with full video input can be used with the PULNiX TM-200, although this camera
model does not come equipped with auto-iris output.
Note:
Make sure that the power is removed from the camera before connecting or disconnecting
the auto-iris lens. There is a small chance that damage could occur to the auto-iris lens by
plugging or unplugging it while the camera is powered up.
Power down the camera before installing the auto-iris lens. To install the auto-iris lens in a PULNiX
camera for which the auto-iris input is not supplied, wire the signal (video) on the lens into the terminal
1 Vp to peak video output on the camera.
Point the camera at a light area and then quickly towards a darker area. If everything is working
properly, the iris should adjust for the light change.
2.2.7 Monitor Display Mode
For monitoring real time video, connect the video output to a video monitor or other device.
Page 7
Need help?