Installation
1 4

Manifold Removal and Installation

The manifold is shipped attached to the insert, but may be removed to facilitate especially tight
installations. See the directions below for installation.
1
Remove the manifold and place it within the fireplace (see the instructions on the following page).
2
Route the flex vent through the chimney from above (leave an extra 3' (914 mm) at the top).
3
Attach the flex vent to the manifold (seal with silicone and attach with screws).
4
Place the manifold in an upright position (so it rests on the manifold legs) and have a partner pull on
the excess flex vent. Temporarily attach the flex vent to the top of the chimney (leave extra slack).
5
Slide the insert into place, guiding the convection top over the insert until fully in place.
6
After removing any slack from the flex vent, attach the manifold to the appliance.
7
Remove any excess slack in the flex line then attach the vent termination.