Vivotek SF8174 User Manual page 232

Fixed dome network camera
Hide thumbs Also See for SF8174:
Table of Contents

Advertisement

VIVOTEK
8.23 Virtual input
Note: Change virtual input (manual trigger) status.
Method: GET
Syntax:
http://<servername>/cgi-bin/admin/setvi.cgi?vi0=<value>[&vi1=<value>][&vi2=<value>]
[&return=<return page>]
PARAMETER
VALUE
vi<num>
state[(duration)nstate]
Where "state" is 0, 1. "0"
means inactive or normal
state while "1" means
active or triggered state.
Where "nstate" is next
state after duration.
return
<return page>
Return Code
Description
200
The request is successfully executed.
400
The request cannot be assigned, ex. incorrect parameters.
Examples:
setvi.cgi?vi0=0(10000)1(15000)0(20000)1
No multiple duration.
setvi.cgi?vi3=0
VI index is out of range.
setvi.cgi?vi=1
No VI index is specified.
503
The resource is unavailable, ex. Virtual input is waiting for next state.
Examples:
setvi.cgi?vi0=0(15000)1
setvi.cgi?vi0=1
Request 2 will not be accepted during the execution time(15 seconds).
232 - User's Manual
(capability.nvi > 0)
DESCRIPTION
Ex: vi0=1
Setting virtual input 0 to trigger state
Ex: vi0=0(200)1
Setting virtual input 0 to normal state, waiting 200
milliseconds, setting it to trigger state.
Note that when the virtual input is waiting for next state, it
cannot accept new requests.
Redirect to the page <return page> after the request is
completely assigned. The <return page> can be a full URL
path or relative path according the current path. If you omit
this parameter, it will redirect to an empty page.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sf8174v

Table of Contents