8.
In the Virtual NetLinx Master Settings dialog box, click OK to close the box.
9.
In the Communications Settings dialog box, click OK to close the box.
10.
In the Master Communications Settings dialog box, click OK to save your settings and return to the main NetLinx
Studio application.
11.
Click the OnLine Tree tab in the Workspace window to view the devices on the Virtual System. The default System
value is 1.
12.
Right-click on the Empty Device Tree/System entry and select Refresh System to re-populate the list.
13.
The OnLine Tree should now display the connection to the device. The Connection Status Icon on the device may
take up to five seconds to register the connection.

Viewing devices on the Virtual System

1.
After the Communication Verification dialog window verifies active communication between the Virtual Master and
the panel, click the OnLine Tree tab in the Workspace window (FIG. 21) to view the devices on the Virtual System.
The default System value is 1.
2.
Right-click on the System entry (FIG. 21) and select Refresh System to re-populate the list. Verify the panel
appears in the OnLine Tree tab of the Workspace window.
FIG. 21
NetLinx Workspace window (showing panel connection via a Virtual NetLinx Master)

Downloading firmware

The panel-specific firmware is shown on the right of the listed panel.
Download the latest firmware file from www.amx.com and then save the Kit file to
your computer. Note that each Kit file is intended for download to its corresponding
panel. In some cases, several Kit files may be included in a .zip file; extract the .zip
file to access the required Kit file.
1.
If the panel firmware version is not the latest available; locate the latest firmware file from www.amx.com.
2.
Click on the desired Kit file link and after accepting the Licensing Agreement, verify download of the Modero Kit
file to a known location.
MXD-430 4.3" Modero X Series® Wall/Flush Mount Touch Panel
The panel will not appear as a device below the virtual system number, in the Online
Tree tab, until both the system number used in step 14 for the Virtual NetLinx Master
is entered into the Master Connection section of the System Settings page and the
panel is restarted.
Upgrading Firmware
Virtual Master firmware
version and device number
Panel firmware version
and device number
23