Configuring Alarm Relays Through The Command Line Interface - GE Multilink ML3000 Instruction Manual

Ethernet communications switch
Table of Contents

Advertisement

MISCELLANEOUS COMMANDS

18.1.2 Configuring Alarm Relays through the Command Line Interface

18–2
Table 18–1: Pre-defined conditions for the ML3000
Event ID
Description
2
Cold Start
3
Warm Start
4
Link Up
5
Link Down
6
Authentication Failure
7
RMON Rising Alarm
8
RMON Falling Alarm
9
Intruder Alarm
11
Broadcast Storm Detected
12
STP/RSTP Reconfigured
To customize these capabilities, the ML3000 provides additional software capabilities and
commands for configuring the alarm relays.
The
command enters the alarm configuration mode
alarm
alarm
The
command enables alarm action in response to the specified event ID.
add
add event=<event-id|list|range|all>
The
command sets the duration of relay action for the momentary type signal.
period
This may be needed to adjust to the behavior of the circuit or relay. The time is in seconds,
with a default of 3.
period time=<1..10>
The
command disables alarm action in response to the specified event ID.
del
del event=<event-id|list|range|all>
The
command globally enables or disables the alarm action.
alarm
alarm <enable|disable>
The
command displays the current status of alarm system
show alarm
show alarm
An example of setting up the external relays and alerts is shown below.
MULTILINK ML3000 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL
CHAPTER 18: MISCELLANEOUS COMMANDS
Signal type
MOMENTARY
MOMENTARY
MOMENTARY
MOMENTARY
MOMENTARY
MOMENTARY
MOMENTARY
MOMENTARY
MOMENTARY
MOMENTARY