ACCESS USING RADIUS
7–10
The following figure illustrates the editing of information for the RADIUS server. Note the
UDP port number can be left blank and the default port 1812 is used.
After configuring the server information, specific port information is configured.
 Select the Configuration > Radius > Port > Set menu item to
configure the RADIUS characteristics of each port.
 To edit the port settings, click on the edit icon (
Ensure that the port which has the RADIUS server is force authorized and asserted. For
other ports (user ports), it is best to leave the Control on auto and Initialize on de-asserted.
MULTILINK ML3000 ETHERNET COMMUNICATIONS SWITCH – INSTRUCTION MANUAL
CHAPTER 7: ACCESS USING RADIUS
).