CONTROL PANEL MEMBRANE SWITCH / RIBBON CABLE TEST

If integrity of control panel assembly is suspect, perform continuity tests at membrane switch ribbon cable terminal
housing. Begin by disconnecting ribbon cable from control board. Disengage control board from control panel.
Remove control panel assembly from unit and place it on solid surface.
Pin 1 Identification Procedure
The ribbon cable wires are exposed at back of terminal housing (see Figure 8-1). If Pin 1 is not labeled on ribbon
cable or terminal housing tag, follow guidelines below to identify Pin 1:
1. If terminal housing is BLUE, then Pin 1 is closest to arrow on housing.
2. If terminal housing is BLACK, check for continuity between first two pins at each end of housing while pushing
UNIT ON/OFF key. If there is continuity, then Pin 1 is at that end.
Continuity Test Procedure
1. Identify model number being serviced in left column of table below.
2. Press key listed at top of table.
3. Corresponding numbers to right of model number and below key being pressed are the pin numbers on terminal
housing that should have continuity.
NOTE: If any continuity tests show failure, replace entire control panel assembly.
UNIT
MODEL
ON/OFF
KEY
601R-2
1 - 2
601RG-2
1 - 2
601F-2
1 - 2
611-2
1 - 2
611G-2
1 - 2
632-2
1 - 2
642-2
1 - 2
650-2
1 - 2
650G-2
1 - 2
661-2
1 - 2
685-2
1 - 2
695-2
1 - 2
Ribbon Cable
Exposed pins on back side of housing.
NOTE: See "How To Identify Pin 1", above.
Figure 8-1. Control Panel Assy with Cut-Away View to Show Ribbon Cable (Model 632 Control Panel Shown)
#3758407 - Revision B - August, 2006
ALARM
ICE
REFRIG
(
)
ON/OFF
WARMER
ON/OFF
KEY
KEY
2 - 5
NA
2 - 5
NA
2 - 5
2 - 3
2 - 5
2 - 3
2 - 3
2 - 5
2 - 5
2 - 3
2 - 5
2 - 3
2 - 5
2 - 3
2 - 3
2 - 5
2 - 5
2 - 3
2 - 3
2 - 5
2 - 3
2 - 5
Built-In
Built-In
(600-
(600-
REFRIG
FREEZER
COLDER
WARMER
KEY
KEY
KEY
3 - 4
4 - 5
3 - 4
4 - 5
NA
NA
3 - 4
1 - 6
5 - 6
3 - 4
3 - 4
4 - 5
1 - 6
1 - 6
5 - 6
3 - 4
1 - 6
5 - 6
3 - 4
1 - 6
5 - 6
3 - 4
3 - 4
4 - 5
1 - 6
1 - 6
5 - 6
3 - 4
3 - 4
4 - 5
1 - 6
3 - 4
4 - 5
1 - 6
FREEZER
COLDER
WARMER
COLDER
8-18
Series
Series
2
2
)
)
FREEZER
BULK
COLDER
ICE
KEY
KEY
NA
NA
NA
NA
NA
NA
4 - 5
NA
4 - 5
NA
5 - 6
NA
4 - 5
NA
4 - 5
NA
4 - 5
NA
5 - 6
NA
4 - 5
NA
5 - 6
1 - 4
5 - 6
1 - 4
ICE
REFRIGERATOR
WARMER
ON/OFF
Membrane Switch in
Control Panel Assembly
LIGHTS
ON/OFF
KEY
NA
2 - 3
NA
NA
1 - 4
NA
NA
NA
1 - 4
NA
NA
NA
UNIT
ON/OFF
ON/OFF

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 601R-2 and is the answer not in the manual?

Questions and answers

Ned Thanhouser
February 22, 2025

How do I adjust defrost cycle temperature in refrigerator 601R? Currently goes to 56 degrees.

1 comments:
Mr. Anderson
February 22, 2025

The defrost cycle temperature in the Sub-Zero 601R refrigerator is controlled by the defrost terminator. For model 601F-2, the defrost terminator cut-in temperature is 30°F (-1°C), and the cut-out temperature is 70°F (21°C). If adjustment is needed, check for proper operation of the defrost terminator and replace it if defective. There is no manual adjustment for these temperatures.

This answer is automatically generated

Table of Contents

Save PDF